Double D Mechanical Services · Preview build
Houston-based · Nationwide installs832-514-9736
Brands · Double D Mechanical

KOCH Finishing Systems for Data Center Racks

Data center rack finishing can include tall frames, rails, doors, panels and brackets coated before electronics, cabling and hardware are fitted. KOCH Finishing Systems powder coating lines and conveyor cure ovens can support repeated rack component finishing. Double D Mechanical installs, relocates and services the booth, oven, exhaust and utility connections around those systems.

Discuss your installation

Brand names identify the equipment discussed. Discuss your equipment model and installation scope with Double D; manufacturer authorization is not implied.

Tall Frames And Perforated Doors

Rack frames and perforated doors need enough clearance through conveyor turns, booth openings and oven entries. Planning should consider part swing, hanger contact, rack rigidity, masked areas and the unload method used to protect finished surfaces.

Part Mix Through One Line

A rack operation may run frames, rails, panels, brackets and doors through the same equipment. The layout should support different hanging methods, grounding checks, color changes, inspection and cooling without creating congestion at the booth or unload end.

Utilities For Powder And Cure

Powder booths, collection equipment and conveyor ovens need compressed air, electrical service, exhaust, make-up air, controls and heat source coordination. Ductwork and roof penetrations should be planned with building structure, fire protection and production access in mind.

  • Document frame height, door width, rail length and rack depth.
  • Map load, clean, coat, cure, cool and unload zones.
  • Confirm power, compressed air, exhaust and replacement air paths.

Keeping Maintenance Reachable

Rack production areas can fill with carts, skids, hooks and packaging. Keep filter doors, collector access, fan drives, oven panels, burner service areas and control cabinets clear so routine work can happen without stopping the entire finishing area.

Project questions

Frequently asked questions

Which rack dimensions matter for line planning?

Frame height, door width, part depth, hanger drop, conveyor turn clearance and oven opening dimensions are especially important.

How can small parts and rack frames share a line?

They can share a line when hanging methods, part spacing, grounding, booth access, cure clearance and unload staging are planned together.

What should be reviewed before relocation?

Review equipment condition, section dimensions, conveyor alignment, duct routes, utility tie-ins and access to the new location.

Why reserve cooling and inspection space?

Cooling and inspection space helps protect finished parts before they move to hardware, electronics-related assembly or packaging.

What photos help with planning?

Photos of the equipment, ceiling, roof access, utilities, ductwork, conveyor path and surrounding production aisles are helpful.

Plan your installation

Bring us the equipment details.

Share the manufacturer, equipment size and plant location to discuss your project.

Request a quote832-514-9736